Perhaps one of OSI's most versatile pieces of
hardware, the Omnilock Quick Adapter allows existing lockset installations
to have the convenience, security, and control of an advanced Electronic
Access Control System. One of the greatest advantages of the QA
is it's ability to be mounted to both sides of the door, thus requiring
authorization for entry and exit!!
The Omnilock Quick Adapter Series of standalone
access control systems allows end users the opportunity to combine
OSI’s famous standalone access control technology with the
proven durability of Schlage D-series Cylindrical lock hardware.
The following locksets can be used with the Omnilock
Quick Adapter. Some locksets require minor modification to the locking
plunger inside the chassis, however each chassis has it's own benifits.
Lockset
Model
Function
Mod
Req.
Features/Benefits
50
Entrance w/Privacy Button
N
Lever must be removed to bypass electronics.
53
Entrance/Office w/Privacy Button
N
Electronics can be bypassed with key.
60
Classrom Security Exit
N
Electronics can be disabled or bypassed with key from outside.
66
Store
N
Electronics can be disabled with key from inside or outside,
however lever must be removed to bypass electronics.
70
Classroom
N
Can disable electronics with key from outside, however lever
must be removed to bypass electronics.
73
Corridor w/Privacy Button
N
Electronics can be disabled or bypassed with key from outside.
80
Storeroom
Y
Electronics can be bypassed with key.
82
Institution
Y
Electronics can be bypassed with key.
85
Hotel/Motel
Y
Electronics can be bypassed with key.
The D-73 Corridor lock is ideal for bathroom-type
applications. If the privacy button is depressed the electronics
are disabled but a key may gain access from the outside. The D-53
Entrance lock functions similarly, but there exists the possibility
that an absent-minded person or a prankster will not release the
turn-button on the inside, thereby leaving the electronics in a
disabled state. The D-60 is perhaps the most versatile lock for
a school application. The lock needs no modification and, in case
of safety lockdown, the electronics may be disabled by rotating
a key in the inside lever’s key cylinder. One of the most
interesting uses of the Quick Adapter is the deployment of TWO Quick
Adapters mated to double-cylinder locks such as the D-82PD. Such
a system yields a powerful Asylum-function “code-in-code-out”
lock suited perfectly for jails, detention facilities, or airport
terminals. End users not only have to enter a code or a card to
get into the facility, they need a code or a card to exit (see Images
below).
Applicable systems are
QA100, QA300, QA500, QA2000, and QP2000.